ProjectSums

Insulation calculator

This calculator answers how many batt or roll packages to buy for walls or an attic from the area, the cavity width, and the coverage on the package.

Calculator

ft²

Wall or attic area.

ft²

From the package label. The 40 ft² default is only a starting point.

%

Default 5%.

Result

27

packages to buy

Area
1,000 ft²
Combined R-value
R-49
R-values add. They do not change the package count. Replace 40 ft² with the number on the label.

Shopping list for this project

You need about 27 packages.

Materials: Insulation packages. Use the square feet printed on the label.

Tools that help

As an Amazon Associate I earn from qualifying purchases.

More tools →

Uninsulated attic recommendations
ClimateENERGY STARDOE range
Zone 1R-30R-30–49
Zones 2–3R-49R-38–60
Zones 4–8R-60R-49–60

How this calculator works

Packages = ceil(area × (1 + extra) / square feet per package). The extra defaults to 5%, so the factor is 1.05, and you can change it. Coverage is the square feet printed on the package. The form starts at 40 ft² per package only so the field is not empty — replace it with the label.

R-values in layers add. The sum does not change how many packages you buy. Match the batt width to the stud spacing: about 15 in for 16 in centers, about 23 in for 24 in centers. Do not compress a thicker batt to make it fit.

ENERGY STAR, for an uninsulated attic, recommends Zone 1 R-30, Zones 2–3 R-49, and Zones 4–8 R-60. The Department of Energy ranges are Zone 1 R-30–49, Zones 2–3 R-38–60, and Zones 4–8 R-49–60. Those tables help you pick a product. They are not the package math.

Source: energystar.gov and the DOE insulation guide.

Worked example (illustrative). 1,000 ft² at 40 ft² per package with 5% extra is 27 packages. An R-30 layer plus an R-19 layer is R-49.

FAQ

Does a higher R-value change the package count?

Only because that product’s package covers a different number of square feet. Thicker insulation is often fewer square feet per bag. Enter the coverage from the package, not the R-number alone.

Which batt width should I buy?

Match the stud spacing. Sixteen-inch centers take the narrower batt; twenty-four-inch centers take the wider one. A batt that is too wide gets compressed and does not perform as labeled.

Do I subtract windows?

Subtract openings you will not insulate. Insulation stops at the frame. Leaving a large window in the area buys batts you cannot use in that opening.

Where do recommended R-values come from?

Climate-zone recommendations are published by the Department of Energy and ENERGY STAR. This page uses them as a way to pick a product. The quantity math uses the package coverage of the product you selected.

Embed this calculator

Free to use on your site. Please keep the credit link.

Preview: open the embed · How embedding works

By ProjectSums Editors · Reviewed against manufacturer data and building-code references · Last updated October 4, 2026

Estimates only. Check product labels, manufacturer instructions and local building codes before you buy or build.